• Genevac
  • VirTis
  • FTS Systems
  • Hotpack
Thermal Management Equipment / Air Stream / ThermoJet ES Precision Temperature Cycling System

 
ThermoJet ES Precision Temperature Cycling System

FTS Systems
ThermoJet ES Precision Temperature Cycling System

ThermoJet Environment Simulator is a precision-controlled temperature forcing system that delivers an airstream of up to 20 SCFM to rapidly change the temperature of a product or Device Under Test (DUT).

ThermoJet provides temperature transition speeds unmatched in the industry, and can sustain air cooling temperatures of –80°C at 20 SCFM. It is made with the proven and reliable Dual Cool cascade refrigeration system and does not require complex and difficult blended gases.

The ThermoJet provides the smallest footprint for a floor model air stream temperature cycling system.

Receive a FREE SH551 Transparent Shroud with the purchase of ThermoJet ES.

Offer good until 12/31/2010

KEY FEATURES

  • Temperature range of +225°C to -80°C
  • High Temperature option of +375°C
  • Delivers 5 to 20 standard cubic feet of air/minute
  • Temperature transition from +200°C to -65°C in less than 15 seconds -80°C to +200°C in less than 15 seconds
  • Reliable and robust Dual Cool cascade refrigeration system does not require difficult blended gases
  • Small footprint allows maximization of space usage
  • External Device Under Test thermocouple for controlling temperature accuracy at the device
  • Configured with no holding arm, pneumatic arm or mechanical arm for easy air stream placement
  • Dry air purge to help protect test site
  • Selection of shrouds and boxes to meet your application
  • Built in air dryer with oil, water and particulate filters
  • Enhanced BTU/watt removal capabilities provided by higher air flow rate
  • Effortless change temperature and air flow set points

KEY BENEFITS

  • Significantly greater heat removal with up to 20 scfm air flow throughout temperature range
  • Decrease testing time with faster transition rates
  • Saves space with smallest footprint for floor model air streams
  • Less downtime and cost with superior, time tested, cascade refrigeration package and globally available, environmentally friendly and inexpensive refrigerants.
  • Avoid costly software conversion by utilizing universally compatible command set
  • Expand performance capabilities with optional thermal chambers.
  • Precise and reliable temperature control for device testing characterization
  • Thermally isolated environments provided by shrouds for precise temperature control

SPECIFICATIONS

SPECIFICATIONS1,2
Temperature
     Maximum Low
-80°C  
     Maximum High Standard +225°C / High Temp +375
     Accuracy
1°C - Factory calibrated with NIST traceable device
     Setability 0.1°C
     Indication/Resolution 0.1°C
     Stability ±0.5°C at discharge nozzle
     Sensors Special limits of error type-T thermocouples
     Calibration Software controlled
     Max. Transition Rates
+125°C to -55°C in <10s / -55°C to +125°C in <10s
+200°C to -65°C in <15s / -80°C to +200°C in <15s
     Stabilization Rate3
+125°C to -55°C in <12s
-55°C to +125°C in <4s
Air Filtering/Drying
     Coalescent
Water, Oil, and Particle Filtering
     Heatless Regenerative
-85°C dew point
Air Flow Specifications
     Input
25 SCFM @ 80-125 psig, dew point 10°C
(11.8 l/s @ 5.5 - 8.6 bar)
     Output
5-20 SCFM (2.3 - 9.4 l/s)
Factory calibrated with NIST traceable device
     Setability 1 SCFM (0.4 l/s)
Physical Characteristics
     Footprint 21” wide x 27” deep (54 cm x 69 cm)
     Arm Reach 56” radius (140 cm) max.
     Rotation 350°
     Work Surface Height 38” (100 cm)
     Weight 425 lbs (193 kg)
     Mobility 4 full swivel, lockable casters
     DB Rating4 @ 65 dB(A)
System Controller Features
     Type
Microprocessor PLC-based PID
     Program
Save and load 48 programs of 8 segments each
     Safeties Low flow, over temp, EMo interlock
     Status Indication
Air input, air temp, air/DUT control,
OK, run/idle, purge, defrost
     Available Limits Max. ramp rate, min./max. air temperatures
     Ramp Rates 1°C/min. incremental up to 999°C
     Remote Information IEEE, RS232 Communication
System Requirements
     Temperature +12°C to +25°C
     Humidity 0% to 65% RH
     Electrical
208V-230V/60Hz, 200V/50Hz @ 1Ph 30A
220V-230V/50Hz @ 1Ph 30A



NOTES:
1. Specifications based on 230V, 60 Hz at 15 SCFM, ambient 23°C, 50% humidity.
2. System may be used with lower pressure at reduced specifications.
3. Clock started when temperature reached setpoint.
4. Operating at low air flow.

APPLICATION EXAMPLES

  • Device cycling and testing
    • Chips
    • Solenoids
  • Plastics molding applications

OPTIONAL COMPONENTS

To configure a THJ to fit your requirements, select options from each of the groups below.  For assistance in determining which option is right for you or to receive a quote, please contact a product specialist.  We will be glad to discuss the options and their importance and use with you.

LITERATURE & ADDITIONAL SPECIFICATIONS

 

Product gallery

Send to a Colleague

Your name:  
Colleague's Email:
Your message (click here):
 



Free Webinar
Key Considerations for the Successful Lyophilization of Proteins
Presented by Jeff Blue, Merck

Click For More Info



SP Scientific is proud to be a sponsor of
Freeze Drying of Pharmaceuticals and Biologicals Conference
9/28 - 10/1
Garmisch Germany
Link to Information



LYOLEARN WEBINAR ARCHIVE
Freeze drying topics
Given by freeze drying experts

Recorded for you to listen to on demand
FOLLOW THIS LINK